STARTING PROCEDURE OF AUXILLARY ENGINE | ||
SL.NO | Description | Yes/No/Na |
LOCAL STARTING | ||
1 | Open the starting air v/v, control air v/v, indicator cock and blow through. | |
2 | Check the line for F.O., cooling water and L.O. | |
3 | Set the operating lever to "START" position. | |
4 | Press the push button for the starting operation v/v. | |
5 | If the rotation speed of the engine has rapidly increased | |
and starting has been established along with continous ignition sound, release the | ||
push button. | ||
6 | After conforming that the rotational speed of the engine has reached the | |
specified speed and each pressure has reached the specified value, set the | ||
operating lever to "RUN" position. | ||
oil. | ||
REMOTE STARTING | ||
1 | switch the starting mode to the remote mode from local mode. | |
2 | Set the operating lever to "RUN" position. | |
3 | Open starting airv/v, control air v/v, after conforming that "READY" indication lamp | |
has lit up in E.C.R. panel. | ||
4 | Press the starting push button. | |
5 | Confirm that "RUN" indicator lamp on the panel has lit up as the rotation speed of | |
the engine has reached the specified rate, and each pressure has reached the | ||
specified value. | ||
6 | Close the starting air v/v | |
STOPPING | ||
1 | Incase of heavy fuel oil is used, switch the fuel oil to D.O. 30 minutes before | |
stopping the engine. | ||
2 | Confirn L.O. priming pump is on "AUTO" mode. | |
LOCAL POSITION | ||
1 | Shift the operating lever to "STOP" position. | |
REMOTE STOPPING | ||
1 | Press the "STOP" push button on the control panel & then press "ENTER" push | |
button on control panel. | ||
2 | Open the indicator v/v, once engine stops, conduct air running for 3 to 4 sec & | |
exhaust the combustion gas out of the combustion chamber. Then close the indicator v/v. | ||